Compensation in flow cytometry pdf

The impact of adjusting pmt voltages on spillover and compensation thomas myles ashhurst1,2,3, adrian lloyd smith3,4 1viral immunopathology laboratory, discipline of pathology, sydney medical school, the university of sydney. Flow cytometry fcm is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles in this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument. There must be a single stain control for every fluorescence parameter in the experiment. The majority of flow cytometers are now digital systems. Loss of sensitivity from spectral crossover unwanted fret. Compensation in flow cytometry unit 1 biocom biotech. Introduction to flow cytometry mouse 101 ccr mouse research models susan sharrow may 22, 2012. Using the generate compensation feature,291 using the logicle scale,297 composite analysis compensation options,298 batch processing,298. The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to. If you choose fluorochromes that are spectrally separate i. In panels a and b, the ratio of the negative, single. Understanding what compensation is, why it is necessary, and what to expect when using it, are critical for generating useful and highquality data from flow cytometry experiments. A beginners guide to flow cytometry 3 a bar placed on the opposite side of the flow chamber blocks the laser beam. Compensation is one of the most critical, and yet poorly understood topics in flow cytometry.

The forward light scatter fsc detector sits behind the blocker bar and this detects light scatter at angles in a forward direction. Why flow cytometry fluorescence compensation is critical. Pe without a and c and with b and d applying compensation. Principles and applications of flow cytometry table of. Single stain controls the purpose of single stain controls is to calculate the spillover between channels.

In cytometry, compensation is a mathematical correction of a signal overlap between the channels of the emission spectra of different fluorochromes the photons emitted by fluorochromes have different energies and wavelengths and as flow cytometers use photomultiplier tubes pmt in order to convert the phonons into electrons, the detector can register the signal from more than one fluorochrome. All fluorochromes have excitation and emission spectra. Compensation is an essential part of proper experimental setup for multicolor assays. Introduction to flow cytometry flow cytometry is a popular laserbased technology. An introduction to spectral overlap and compensation. Among the first 50 or so, i found a few that propound these myths. Add 2 ml of flow cytometry staining buffer to each tube and centrifuge at 400600 x g for 35 minutes. Fl1fl3 then compensation samples are not necessary. The more colors you use, the more problems you will have. This information can be used to individually sort or separate subpopulations of cells. Mix briefly by flicking or pulse vortexing before analysis. Calculating compensation manually to bd facsdiva software reference manual.

Fluorescence spectral overlap compensation for any number of flow cytometry parameters. Cyteks aurora spectral cytometer has a rapidly growing presence among flow cytometry research instruments. Controls, compensation and calibration information thermo. Flow cytometry is the technical process that allows for the individual measurements of cell fluorescence and light scattering. Understanding compensation is rooted in an understanding in the physics of fluorescence. Compensation controls must match the exact experimental. Facs is an abbreviation for fluorescenceactivated cell sorting, which is a flow cytometry technique that further adds a degree of functionality. In private email discussions following the exchange about compensation, i found that there are still outstanding incorrect beliefs and myths about analog compensation. The right negative compensation control is unstained cells the right positive compensation control is the brightest reagent for each color stained alone. Recent advances in fluorescenceactivated cell sorting facs technology offer new. Feb 21, 2018 flow cytometry is a technology that rapidly analyzes single cells or particles as they flow past single or multiple lasers while suspended in a buffered saltbased solution. The goal of color compensation is to correctly quantify each dye with which a particular cell is labeled.

Forward light scatter is an indication of cell size. Compensation controls data visualization panel development. Compensation in multicolor flow cytometry request pdf. In flow cytometry, the emission spectral overlap of fluorescein and rphycoerythrin is usually corrected by electronic color compensation using microspheres surface labeled with the same. Jul 10, 2018 compensation in flow cytometry webinar speaker. After collecting data for all necessary compensation samples, generate the compensation matrix by selecting compensation calculation from toolbar or settings menu. Quick tips and tricks for flow cytometry include unstained controls, single color controls, and experimental controls for your experiments. Basic data analysis, gating, and statistics in flow cytometry. Datadriven compensation for flow cytometry of solid tissues nickolaas maria van rodijnen, 1 math pieters, 1 sjack h oop, 1 and marius nap 1, 2 1 department of pathology, atrium medical centre, p. The compensation matrix window appears displaying the compensation values.

Shaprios practical flow cytometry from beckman coulter addeddate 20170312 09. Imaging flow cytometers ifc combine traditional flow cytometry with fluorescence microscopy. Compensation in multicolor flow cytometry szaloki 2015. Each particle is analyzed for visible light scatter and one or multiple fluorescence parameters. Additional resources for understanding compensation. Presently, more than 40,000 journal articles referencing flow cytometry have been published. Compensation controls single stains one for each fluorochrome used in the experiment cd8 cy5pe 6 7 cd3 fitc cd8 cy5pe 8. Todays guest speakers are graham pockley and ian dimmick. Flow cytometry is a popular cell biology technique that utilizes laserbased technology to count, sort, and profile cells in a heterogeneous fluid mixture. Discover more with our introduction to flow cytometry.

Flow cytometry friday, december 14, 2018 10am, wimr 7001a overview of computational data analysis platforms for flow cytometry friday, january 11, 2019 10am, wimr 7001a flow cytometry compensation with confidence friday february 1, 2019 10am, wimr 7001a flow cytometry current best practices for pis thursday, february 14, 2019 7. Hello, and welcome to abcam s webinar on color compensation in flow cytometry. Pdf datadriven compensation for flow cytometry of solid. The impact of adjusting pmt voltages on spillover and compensation thomas myles ashhurst1,2,3, adrian lloyd smith3,4 1viral immunopathology laboratory, discipline of pathology, sydney medical school, the university of sydney 2marie bashir institute for infectious disease and biosecurity mbi, the university of sydney 3ramaciotti facility for human systems biology rfhsb. Compensation in flow cytometry roederer 2002 current.

Roderer, modified by the facs core five steps must be taken to assure proper compensation. Ifc can track protein distributions within individual cells like a confocal or fluorescence. This process is performed at rates of thousands of cells per second. Fluorescence compensation one consideration when performing multicolor fluorescence studies is the possibility of spectral overlap between fluorophores. Rapid, quantitative, single cell fluorescence analysis and cell. Setting compensation properly requires the use of right controls.

Controls need to be at least as bright or brighter than any sample the compensation will be applied to. Please refer to the manufacturers instructions and software manual for a more detailed compensation procedure for your instrument. This article describes why compensation is required for flow cytometry and how to apply it. Flow cytometry is a technology that simultaneously measures and then analyzes multiple physical characteristics of single particles, usually cells, as they.

Jul 09, 2016 compensation is one of the most critical, and yet poorly understood topics in flow cytometry. This is the job of the signal processing electronics. Roderer, modified by the facs core five steps must be. However, it is also a subject that many flow cytometry users find difficult and confusing. Compensation controls are necessary when using more than one fluorochrome in a sample that has spectral overlap on the emissions spectra i. Why flow cytometry fluorescence compensation is critical for. Compensation requires using single stained cells rather than a tube of cells. Color compensation in flow cytometry webinar abcam. Fluorescent compensation flow cytometry guide biorad. Compensation multiple instrument correlation laboratory monitors and verifies daily that flow cytometer performance is consistent with established specifications flow cytometers used in clinical arena are generally black box technology with most of the instruments setup being established during manufacturer or delivery. Flow cytometry is now a widely used method for analyzing the expression of cell surface and intracellular. Flow cytometry facs troubleshooting guide facs antibodies. Flow cytometry analysis software manufactured by beckman coulter, inc.

An introduction to compensation for multicolor assays on. Controls, compensation and calibration information. This is done by subtracting a portion of one detectors signal from another, leaving only the desired signal. The properties measured include a particles relative size, relative granularity or internal complexity, and relative. Compensation is a mathematical process which corrects multiple. Compensation to correct for spectral overlap during multicolor. Event rate is too high due to air in flow cells andor sheath filter. The impact of adjusting pmt voltages on spillover and. Grahams research areas are focused on immunoregulatory mechanisms in health and disease, and he is currently the associate director of the john van geest cancer research centre at nottingham trent university. Flow cytometry flow cytometry is the technical process that allows for the individual measurements of cell fluorescence and light scattering. Controls, compensation and calibration are all critical to obtaining accurate results in flow cytometric analysis. Compensation in multicolor flow cytometry gabor szaloki, katalin goda key terms flow cytometry.

1584 1299 1400 1570 747 1506 621 1580 872 115 997 576 798 691 422 706 386 426 290 175 331 854 2 1046 220 1013 816 177 946